How galvanic oxygen cells work, how they fail, and why calibration alone is not enough.

01 · THE MEASUREMENT

What does an oxygen sensor actually measure?

A CCR oxygen sensor is used to determine the partial pressure of oxygen (PPO₂) in the breathing loop. It does not simply report oxygen percentage. Partial pressure depends on oxygen fraction and ambient pressure.

PPO₂ = FO₂ × Pambient

Air at approximately 1 bar has a PPO₂ of about 0.21 bar. The same 21% oxygen at 20 m, at approximately 3 bar absolute, has a PPO₂ of about 0.63 bar. The fraction is unchanged, but the partial pressure has tripled.

02 · INSIDE THE CELL

How a galvanic oxygen cell produces a signal

A typical galvanic CCR oxygen cell contains an oxygen-permeable membrane, a cathode, a lead-based anode and electrolyte. Oxygen diffuses through the membrane and participates in electrochemical reactions that generate electrical current.

Within the useful operating range and under stable conditions, increasing PPO₂ increases oxygen diffusion and therefore the generated current. The measurement circuit converts this response into the millivolt signal interpreted by the CCR electronics.

Measurement chain: O₂ partial pressure → membrane diffusion → electrochemical reaction → current → mV → CCR electronics → displayed PPO₂.

Technical basis: Kevin Gurr, Oxygen Sensors and Their Use within Rebreathers (2013).

03 · MILLIVOLTS

From sensor output to displayed PPO₂

Calibration establishes a relationship between electrical output and a known oxygen partial pressure. A simplified teaching relationship is:

PPO₂(current) ≈ mV(current) / mV(reference) × PPO₂(reference)

If the electrical response ceases to remain proportional, a reasonable calibration at one point does not guarantee an accurate value at another PPO₂.

04 · CALIBRATION

What calibration does — and what it does not do

Calibration establishes a reference between a known PPO₂ and sensor output. It does not regenerate an ageing cell, increase the maximum current it can deliver, or demonstrate full-range linearity.

Calibration answers: What output corresponds to this known PPO₂?

It does not automatically answer: Will the sensor continue to respond proportionally at a substantially higher PPO₂?

Divesoft warns that an oxygen sensor near end of service life can successfully undergo low-PPO₂ calibration while no longer being capable of measuring around 1 bar or higher. Its Liberty procedure also requires waiting for mV stabilisation before calibration.

Divesoft CCR Liberty Manual: part 02 and part 03.

05 · REPEATED CALIBRATION

Why repeated calibration can create false confidence

Imagine a CCR that begins the calibration sequence with a loop PPO₂ around 0.19. When calibration is initiated, oxygen is added and the oxygen fraction around the sensors rises. The sensor mV therefore rises as the physical gas composition changes.

If a second calibration subsequently produces a higher value, it is tempting to conclude that the cells “needed another calibration” or that the second calibration improved them. Calibration, however, does not restore or strengthen the electrochemical cell.

Gas replacement comes before the reference

During the transition from a diluent-rich loop toward the oxygen-rich calibration condition, residual gas is progressively displaced. The sensor signal should rise as the PPO₂ around the cells rises. A valid calibration reference requires that this physical condition has become sufficiently stable.

Gas replacement → stable sensor mV → calibration.

If the physical reference condition is different between two calibration attempts — for example because more residual diluent has been displaced, the oxygen concentration around the cells has increased further, or the sensor response has had additional time to stabilise — the second attempt can show a different mV response. That does not mean the first calibration made the sensor healthier.

The cells did not improve because they were calibrated twice. The physical reference condition changed between the two calibration attempts.

What about raising the setpoint first?

Bringing the loop PPO₂ up before starting calibration can reduce the amount of gas-composition change still required, but a setpoint such as 0.70 is not itself the calibration reference. It should therefore not be presented as an alternative calibration procedure unless it is specified by the manufacturer.

For JJ-CCR, the important manufacturer-specific point is that the calibration sequence adds oxygen and waits for the oxygen-cell mV values to stabilise. The calibration reference is determined from the calibration gas and ambient pressure — not simply from the normal operating setpoint.

Manufacturer reference: JJ-CCR current manuals and downloads. Exact calibration procedure should always follow the current manual for the installed JJ-CCR electronics/software version.

06 · LINEARITY

Why calibration does not prove linearity

A healthy cell should respond approximately proportionally to PPO₂ through its intended range. One-point calibration establishes one point on that response curve. It cannot demonstrate the shape of the curve above that point. This distinction becomes critical when a cell develops current limitation.

07 · CURRENT LIMITATION

What physically happens when a cell becomes current limited?

A galvanic cell has a finite ability to deliver current. As active materials are consumed and the cell ages, its maximum available current can fall. At lower PPO₂ the demanded current may remain below that limit and the sensor can appear normal.

At higher PPO₂, the required output can reach the cell's current limit. Further increases in oxygen pressure then fail to produce the expected proportional rise in output, so the response curve flattens.

Actual PPO₂HealthyIllustrative limited
1.001.001.00
1.201.201.17
1.301.301.19
1.401.401.20
1.601.601.21

Illustrative values only — not specifications for a particular cell.

Oxygen sensor linearity and current limitation
O₂ sensor linearity and current limitation: a healthy sensor continues to increase its output with rising PPO₂, while a current-limited sensor begins to flatten and can under-read the actual PPO₂.

rEvo technical material describes this flattening failure mode and also discusses temporary apparent recovery after a limited cell has spent time at low PPO₂.

rEvo — Understanding Oxygen Sensors.

08 · TEMPERATURE

Why temperature affects oxygen-cell behaviour

Oxygen must diffuse through the sensor membrane before reacting electrochemically. Membrane diffusion is temperature dependent. Cells therefore use temperature compensation, commonly involving a thermistor.

During rapid temperature change the membrane and compensation element need not respond at exactly the same rate. Temporary tracking error can therefore occur while the system reaches thermal equilibrium. This is one reason calibration requires stable conditions.

Technical basis: Kevin Gurr (2013). Numerical examples in that older paper should not be treated as universal specifications for modern cells.

09 · HUMIDITY & CONDENSATION

The membrane is part of the measurement system

Water or contamination on the membrane can change oxygen diffusion and therefore sensor response. A CCR is a warm, humid environment where condensation is possible.

A sensor need not fail completely for moisture to matter. It can eventually show a plausible value while responding more slowly than expected, which is why dynamic behaviour matters as well as the final number.

10 · RESPONSE TIME

A correct final reading can still hide an unhealthy response

Response is often described using T90: the time required to reach 90% of the final response after a step change. Membrane condition, moisture, contamination and ageing can influence response speed.

Correct final PPO₂ ≠ proof of healthy response time.

11 · MULTIPLE CELLS

Why CCRs use more than one oxygen sensor

Multiple sensors provide redundancy and make disagreement detectable. What they do not provide is an independent physical reference for PPO₂. If two sensors develop a similar failure, their agreement does not make their common value correct.

Agreement is useful evidence. Agreement is not the same thing as accuracy.

12 · VOTING LOGIC

Voting identifies disagreement — not physical truth

Voting logic can reject an outlying sensor, which is useful for a single-cell fault. But consider readings of 1.18, 1.19 and 1.42. The higher value cannot automatically be labelled faulty: the two lower cells may both be current limited.

Divesoft explicitly warns that an excluded sensor can be the only correctly working sensor while the remaining sensors are limiting, and notes the increased risk of excluding a valid sensor when comparison is reduced to two current-limited cells.

Divesoft CCR Liberty Manual — sensor exclusion logic.

13 · COMMON-MODE FAILURE

Redundancy does not guarantee independence

Sensors installed in the same CCR can share temperature, humidity, oxygen exposure, storage history and similar age or production characteristics. More than one cell can therefore develop similar behaviour. This is the difference between having redundant measurements and having an independent physical validation of PPO₂.

14 · VALIDATION

Why elevated-PPO₂ validation can reveal what calibration cannot

If current limitation only appears when a sensor is required to produce more current, a higher known or predictable PPO₂ can expose behaviour that is invisible near the calibration point.

The method must be specific to the rebreather and manufacturer procedure. This is not a reason to improvise high-PPO₂ tests. Controlled cell testers and manufacturer-defined procedures exist because the reference condition must itself be known.

15 · JJ-CCR EXAMPLE

Connecting the physics to a real CCR

JJ-CCR provides a useful practical example because individual sensor behaviour and electrical output can be observed as part of the unit's sensor management. Stable output before accepting calibration follows directly from the measurement physics: calibration needs a stable signal at a known reference.

The official JJ-CCR download area currently lists User Manual Version 3.04 for the DiveCAN unit. Exact calibration, pre-dive and elevated-PPO₂ procedures should therefore be taken from the current manual.

JJ-CCR current downloads →

16 · SENSOR COMPATIBILITY

Why galvanic oxygen cells are not automatically interchangeable

Cells using the same basic electrochemistry can differ in dimensions, connectors, output, electrical load, membrane characteristics, response time, compensation and approved operating range.

Divesoft provides a clear example: its current Liberty manual specifies R22D-type oxygen sensors and prohibits substitution with other sensor types. Liberty uses four oxygen sensors, two connected to each control unit, with both control units sharing the sensor data.

Physical fit ≠ system compatibility ≠ manufacturer approval.

Divesoft CCR Liberty Manual, section 1.9.2 →

17 · READING THE SYSTEM

Recognising abnormal sensor behaviour

No single displayed number describes sensor health. Useful evidence includes plausible individual mV values, expected direction of response when loop PPO₂ changes, normal response speed, continued tracking across the relevant range and the result of manufacturer-defined validation procedures.

A believable PPO₂ should therefore be supported by believable sensor behaviour.

18 · SUMMARY

Understanding the number on the handset

A CCR oxygen sensor is an electrochemical measurement device. Oxygen diffuses through a membrane, participates in a chemical reaction and produces an electrical signal. The CCR converts that signal into displayed PPO₂.

Calibration establishes a reference but cannot prove full-range linearity. Current limitation can allow a cell to appear normal near the calibration point and under-read as PPO₂ rises. Temperature, moisture and response time can also influence behaviour.

Multiple sensors and voting provide valuable redundancy, but they do not create an independent physical reference. Two failing sensors can agree and potentially outvote a correctly responding sensor.

The central principle: understand not only the PPO₂ displayed by the CCR, but where that value comes from, how the sensor should respond, and how a plausible measurement can become wrong.

REFERENCES

References & further reading

Kevin Gurr — Oxygen Sensors and Their Use within Rebreathers (2013)

Technical basis for galvanic-cell chemistry, membrane diffusion, temperature, humidity, response time, calibration, current limitation and voting concepts.

JJ-CCR — Current manuals

JJ-CCR Downloads →

Divesoft — CCR Liberty User Manual

Current online manufacturer documentation used for calibration, sensor exclusion, voting limitations, validation and sensor compatibility. Liberty Manual →