KNOWLEDGE · DIVING PHYSIOLOGY

NARCOSIS
& END

Narcosis is a pressure-related impairment that can affect judgment, attention, reaction time and task performance. Technical divers use helium and Equivalent Narcotic Depth as planning tools to manage that exposure.

DEPTH ↑ · NARCOTIC GAS PARTIAL PRESSURE ↑NARCOTIC EFFECT GENERALLY INCREASES WITH DEPTH
THE PHYSIOLOGY

FEELING FINE DOES NOT MEAN PERFORMING FINE.

Nitrogen at elevated partial pressure has a narcotic effect. DAN notes that effects are commonly noticeable around 80–100 ft (about 24–30 m), vary among individuals and can vary between dives.

Narcosis can alter reaction time, judgment and performance. In technical diving that matters because cognitive workload often increases at the same time: equipment, team communication, gas switches and decompression all demand attention.

WHY HELIUM

REDUCE NARCOTIC LOAD — AND GAS DENSITY.

Nitrogen

Nitrogen becomes narcotic as its partial pressure increases.

Helium

Helium is used in technical mixtures because it is substantially less narcotic and much less dense than nitrogen.

Trimix

Bottom-gas selection must consider END together with PO₂, density, decompression and operational requirements.

EQUIVALENT NARCOTIC DEPTH

STATE THE ASSUMPTION.

There is more than one END convention. The number changes depending on whether oxygen is treated as narcotic, so an END value without its assumption is incomplete.

N₂-ONLY NARCOTIC ASSUMPTION
END = ((FN₂ × Pabs) ÷ 0.79 − 1) × 10

Compares nitrogen partial pressure in the mix with nitrogen partial pressure in air.

HELIUM-ONLY NON-NARCOTIC ASSUMPTION
END = ((1 − FHe) × Pabs − 1) × 10

Treats oxygen and nitrogen as contributing to narcotic depth. Current GUE standards explicitly define END with helium as the only non-narcotic component.

WORKED EXAMPLES · VERIFIED

SAME GAS — DIFFERENT ASSUMPTION.

18/45 @ 60 m

N₂-only assumption
END ≈ 22.8 m
((0.37×7)/0.79−1)×10

18/45 @ 60 m

He-only non-narcotic
END = 28.5 m
((0.55×7)−1)×10

18/35 @ 60 m

N₂-only assumption
END ≈ 31.6 m
((0.47×7)/0.79−1)×10

Important: examples use the simple seawater approximation Pabs = depth/10 + 1. Do not compare END values calculated with different narcotic assumptions as though they were equivalent.

CO₂ & PERFORMANCE

END IS NOT THE WHOLE STORY.

Dense gas and high workload can impair ventilation and increase CO₂. DAN notes that hypercapnia can increase nitrogen narcosis. Gas-density planning and END planning therefore belong together.

DENSITY / WORK↑ CO₂MORE COGNITIVEIMPAIRMENT
INSTRUCTOR INSIGHT

“END is a planning number, not a measurement of how narcosed a diver will feel. Use it to create cognitive margin — not to prove that a gas is safe.”

KIM HENRIKSEN · TECDIVINGDK
REFERENCES

OPERATIONAL BASIS.

DAN · Breathing Gases

Nitrogen narcosis and helium use in mixed-gas diving.

DAN reference →

GUE · Standards v10.1

Defines a 30 m / 100 ft END limit and assumes helium is the only non-narcotic component.

GUE standards →

DAN · Your Lungs and Diving

Discusses hypercapnia and its relationship with nitrogen narcosis and other diving risks.

DAN reference →