M-VALUES
M-values define the modeled upper inert-gas pressure tolerated by a theoretical tissue compartment at a given ambient pressure. They are fundamental to Bühlmann decompression — and the reference boundary that Gradient Factors modify.
A PRESSURE-DEPENDENT MODEL LIMIT.
Each Bühlmann compartment has coefficients that define a straight M-value line. The line specifies the maximum modeled inert-gas pressure for that compartment as ambient pressure changes.
An M-value is not a fixed tissue pressure and it is not a physiological cliff. It is a mathematical boundary used by the decompression model.
THE LINE COMES FROM a AND b.
Ptol is the tolerated compartment inert-gas pressure predicted by the model, Pamb is ambient pressure, and a and b are compartment-specific Bühlmann coefficients.
a coefficient
Controls the intercept of the M-value relationship and differs between compartments and inert gases.
b coefficient
Controls the slope relationship with ambient pressure and also varies by compartment and inert gas.
Compartment
Each theoretical compartment has its own half-time and coefficients, so the controlling compartment can change during ascent.
ONE COMPARTMENT AT 10 M.
For an illustrative ZHL-16C nitrogen calculation, take compartment 5 with a 27-minute N₂ half-time, a = 0.6200 bar and b = 0.8126. At approximately 10 m seawater, Pambient ≈ 2.0 bar.
The modeled M-value gradient above ambient pressure is 3.081 − 2.000 = 1.081 bar.
This does not mean the actual compartment pressure is 3.081 bar. It calculates only the model boundary for this example compartment at this ambient pressure.
ASCENT CREATES THE GRADIENT.
During ascent, ambient pressure falls. The modeled inert-gas pressure in a theoretical compartment may then become greater than ambient pressure. This condition is supersaturation, and the pressure difference between compartment inert-gas pressure and ambient pressure is the supersaturation gradient. In the Bühlmann model, that gradient may increase during ascent until the compartment reaches its pressure-dependent M-value boundary.
GF SCALES THE AVAILABLE GRADIENT.
GF 0% represents the ambient-pressure line, while GF 100% represents the original M-value line. Values between 0% and 100% represent a fraction of the available M-value gradient. A GF below 100% therefore creates a more conservative modeled ceiling than the unmodified M-value.
For a detailed explanation of GF Low, GF High and settings such as 30/70, continue to the dedicated Gradient Factors article.
“The M-value is not where decompression sickness suddenly begins. It is the model's reference boundary. Gradient Factors decide how much of that modeled gradient we are willing to use.”
UNDERSTAND THE BOUNDARY.
Not one M-value
Every compartment has its own coefficients, and the tolerated value changes with ambient pressure.
Not a safety wall
M-values are model limits, not a guarantee that decompression sickness cannot occur below them.
GF modifies the limit
Gradient Factors reduce the fraction of the original M-value gradient used for decompression planning.
THE SCIENCE BEHIND M-VALUES.
These are the sources used to support the decompression-model concepts on this page. Each reference includes a short note explaining why it is relevant.
Bühlmann, A.A.
Baker, E.C.
Baker, E.C.
Divers Alert Network
Shearwater Research
Bühlmann ZHL-16C
An M-value is a model-derived pressure limit for a theoretical compartment. It is not a measured anatomical breaking point and it is not a guaranteed boundary between “safe” and “unsafe” decompression.
