KNOWLEDGE · HELIUM

HELIUM &
THERMAL CONSIDERATIONS

Helium solves important problems in deep diving: it reduces gas density and nitrogen narcosis. But helium also changes the thermal characteristics of the gas around the diver. Understanding where that matters — and where it does not — is part of intelligent trimix and CCR planning.

HELIUMLOW DENSITYHIGH THERMAL CONDUCTIVITYBREATHINGEXPOSURE
START WITH THE PRINCIPLE

HELIUM MOVES HEAT THROUGH GAS VERY EFFECTIVELY.

Helium has a much higher thermal conductivity than air. Around room temperature, representative values are roughly 0.151 W/(m·K) for helium and 0.026 W/(m·K) for air.

0.151 ÷ 0.026 ≈ 5.8×

This comparison describes thermal conductivity of the gases under reference conditions. It does not mean a diver loses body heat exactly 5.8 times faster.

THE IMPORTANT DISTINCTION

BREATHING HELIUM ≠ FILLING THE SUIT WITH HELIUM.

Breathing gas

Helium in trimix or a CCR diluent is breathed through the respiratory system. Respiratory heat loss exists, but this is not the same thermal pathway as suit insulation.

Drysuit inflation

Gas inside the drysuit forms part of the insulation system. A helium-rich inflation gas conducts heat more effectively than air or argon and is therefore undesirable for thermal protection.

Water exposure

Water removes heat from the body very efficiently. Exposure protection, duration, workload and water temperature remain central to thermal planning.

WHY USE A SEPARATE SUIT INFLATION GAS?

THERMAL PROTECTION IS ONLY PART OF THE REASON.

On helium-based technical dives, a dedicated drysuit inflation cylinder can do more than keep helium-rich gas out of the suit. It separates the thermal and buoyancy function of the drysuit from the diver's primary breathing-gas supply.

THERMAL

Helium has high thermal conductivity. Using helium-rich bottom gas in the drysuit can reduce the insulating effectiveness of the gas layer compared with air or argon.

GAS MANAGEMENT

Every suit inflation taken from back gas consumes breathing gas. A dedicated inflation cylinder prevents routine drysuit operation from drawing down gas that may be part of the diver's bottom-gas or emergency reserve.

SYSTEM INDEPENDENCE

A separate inflation source reduces dependence on the primary breathing-gas system. The exact benefit depends on the diver's configuration and failure-management procedures.

WHY ARGON?

SUIT GAS HAS A DIFFERENT JOB.

Argon has lower thermal conductivity than air and much lower thermal conductivity than helium, so it is sometimes selected specifically as drysuit inflation gas. Air is also commonly used. The purpose is not to create another breathing gas — it is to provide a suitable gas for suit-volume control and thermal insulation.

Important nuance: simply connecting an argon cylinder does not mean the suit immediately contains mostly argon. Air already trapped in the suit and undergarments dilutes the inflation gas. Pre-dive purge-and-refill cycles can increase the argon concentration. Controlled human studies that deliberately flushed the suit with argon have nevertheless not consistently shown a measurable improvement in core temperature, skin temperature or thermal comfort compared with air. The lower thermal conductivity is real, but the practical benefit depends on the complete suit, undergarment, gas distribution and exposure conditions.

DRYSUITDEDICATED INFLATION GASINDEPENDENT SOURCE
HELIUM DIFFUSION

Helium is highly diffusive and permeates some materials more readily than nitrogen or argon. This is a relevant physical property of helium, but it should not be confused with the main operational reasons for choosing a separate suit-inflation gas.

DO NOT CONFUSE THIS WITH ICD OR HPNS

Helium in the drysuit is not automatically the same problem as a breathing-gas ICD switch. Isobaric Counter Diffusion concerns opposing inert-gas movements under particular exposure conditions and requires its own analysis. Likewise, HPNS is associated with high-pressure helium exposure at very great depths — not simply with helium being present inside a drysuit.

HELIUM · MATERIALS & PERMEATION

SMALL ATOMS MOVE THROUGH SOME MATERIALS EASILY.

Helium is a small, light atom and can permeate many elastomers and polymeric materials relatively readily. Permeation depends on both how the gas dissolves in a particular material and how rapidly it diffuses through it, so the practical behaviour depends strongly on material composition, pressure, temperature, thickness and exposure time.

Gas → dissolves in material → diffuses through material → leaves material

This process is called permeation. It is different from a conventional leak through a hole or imperfect seal.

HELIUM-RICH GAS POLYMER / ELASTOMER OTHER SIDE

This is relevant to technical equipment because seals, bladders, hoses, membranes and other non-metallic components may interact differently with helium than with air. It does not mean that every component will visibly leak helium; material-specific permeability determines the practical effect.

HELIUM · HUMAN TISSUES

THE SAME WORD — DIFFUSION — ALSO APPLIES IN THE BODY.

During a helium-containing dive, helium moves between the breathing gas, blood and tissues according to partial-pressure gradients. Different tissues and inert gases are represented differently in decompression models because gas uptake and elimination are not identical.

Helium and nitrogen differ in both diffusivity and solubility, so their transport and modeled uptake/elimination kinetics are not identical. It is therefore too simple to teach that “helium is faster.” The relevant behaviour depends on the gas, the tissue or model compartment, the pressure gradients and the exposure history.

Important: decompression compartments are mathematical representations of gas kinetics. They are not literal anatomical boxes corresponding one-to-one with muscle, fat, brain or other specific tissues.

BREATHINGGAS BLOOD TISSUES PARTIAL-PRESSURE GRADIENTS DRIVE TRANSFER He AND N₂ CAN MOVE AT DIFFERENT RATES
HELIUM IN THE DRYSUIT · SUPERFICIAL ICD

THIS IS A DIFFERENT ICD MECHANISM FROM A BREATHING-GAS SWITCH.

We already cover breathing-gas ICD separately in the TecDivingDK Knowledge Centre. Here the important question is more specific: what can happen if a diver is surrounded by helium-rich suit gas while breathing a more nitrogen-rich gas?

THE CLASSIC DIRECTION OF CONCERN

Experimental hyperbaric work has demonstrated superficial isobaric counterdiffusion when subjects breathed a nitrogen-containing gas while their skin was surrounded by helium. Helium can move from the external environment into superficial tissues rapidly, while nitrogen is simultaneously moving from blood and tissues toward the skin and outward.

He IN through skin + N₂ OUT toward suit

Because the two inert gases move differently, their opposing fluxes do not necessarily cancel. Local total inert-gas tension can temporarily rise enough to create supersaturation and bubbles in superficial tissues.

SKIN /SUPERFICIAL TISSUE HELIUM-RICHSUIT GAS He IN N₂ IN BLOOD& TISSUES N₂ OUT AMBIENT PRESSURE CAN REMAIN CONSTANT

1 · HELIUM SURROUNDS THE SKIN

Helium-rich drysuit gas creates an external helium partial-pressure gradient across the skin.

2 · NITROGEN IS INSIDE

If the diver is breathing or has tissue loading from nitrogen, nitrogen may be moving in the opposite direction toward the surface.

3 · LOCAL SUPERSATURATION

Different transport rates can transiently increase total inert-gas tension in superficial tissue and promote bubble formation.

Observed effects: classic human hyperbaric experiments reported itching and gas-bubble skin lesions when nitrogen-containing gas was breathed while the body was surrounded by helium. This is the historical basis for concern about using helium-rich gas in an exposure suit.

PRACTICAL TECH-DIVING MEANING

WHY WE AVOID HELIUM-RICH DRYSUIT INFLATION GAS.

THERMAL

Helium is a poor choice for suit insulation because of its high thermal conductivity.

SUPERFICIAL ICD

A helium-rich environment surrounding the skin while nitrogen-containing gas is present internally is the classic experimental direction associated with superficial ICD. The mechanism depends on opposing inert-gas fluxes and their different transport properties.

SYSTEM DESIGN

A separate air or appropriately managed suit-inflation source avoids deliberately surrounding the diver with helium-rich bottom gas and can preserve breathing gas.

Do not overstate the risk: the classic evidence comes largely from controlled hyperbaric and saturation-type exposures, not ordinary short drysuit inflations on every trimix dive. It therefore does not mean that helium in a drysuit automatically produces ICD. The mechanism is nevertheless real, and avoiding helium-rich suit inflation also has clear thermal and gas-management advantages.

ICD · TWO DIFFERENT PATHWAYS

RESPIRATORY AND SUPERFICIAL ICD ARE NOT THE SAME THING.

The dedicated Isobaric Counter Diffusion Knowledge article covers breathing-gas switches and deep-tissue/inner-ear considerations in more detail. On this page, the focus is the superficial pathway created by the gas surrounding the diver.

Respiratory ICD

Concerns inert-gas exchange through the lungs and circulation after a breathing-gas change. This is the context relevant to helium-to-nitrogen gas-switch planning and rules such as the operational Rule of Fifths.

Superficial ICD

Can occur when the skin is exposed to one inert gas while the body contains another. Historically, helium-rich ambient environments and nitrogen breathing have been associated with superficial counterdiffusion phenomena.

Drysuit context

This is why “helium in the suit” and “helium in the breathing gas” should not simply be treated as identical exposures. The route of gas exchange matters.

Do not oversimplify: the presence of helium in a drysuit does not automatically mean clinically significant ICD will occur. Exposure pressure, gas composition, gradients, duration and the direction of the gas change all matter.

A COMMON OVERSIMPLIFICATION

“HELIUM MAKES YOU COLD” NEEDS CONTEXT.

Helium's high thermal conductivity is real, but the practical thermal effect depends on where the helium is. Helium-rich gas inside the drysuit is part of the insulation system and is therefore undesirable compared with a lower-conductivity suit gas. Helium in the breathing mix is a different exposure pathway and should not be treated as equivalent to filling the suit with helium.

For technical divers, the useful lesson is therefore not simply “helium is cold.” It is: separate breathing-gas requirements from thermal-protection requirements.

RELATED PHYSIOLOGY

THERMAL STRESS & DECOMPRESSION.

Thermal conditions can influence more than comfort. Temperature, workload and active heating can affect circulation and therefore the conditions under which inert gases are taken up and eliminated.

This interaction deserves separate treatment because thermal conditions during the working phase of a dive and during decompression can have different physiological implications. The dedicated Thermal Stress & Decompression Knowledge article covers this relationship in detail.

INSTRUCTOR INSIGHT

“Helium is chosen because it improves the breathing gas at depth. That does not mean it is the gas we want surrounding the diver inside a drysuit.”

KIM HENRIKSEN · TECDIVINGDK
THREE PRINCIPLES

GIVE EACH GAS A JOB.

Helium for depth

Helium can reduce gas density and nitrogen narcosis in deep breathing mixtures.

Suit gas for insulation

Avoid treating helium-rich breathing gas as an ideal drysuit inflation gas.

Plan thermal exposure

Water temperature, duration, workload, decompression and heating strategy all influence thermal stress.

REFERENCES & FURTHER READING

THE SCIENCE BEHIND THE ARTICLE.

The physiological and thermal statements on this page are based on published diving and hyperbaric research. The references below are included so the reader can distinguish established experimental findings from operational interpretation.

Lambertsen CJ, Idicula J. · 1975

A new gas lesion syndrome in man, induced by “isobaric gas counterdiffusion”. Journal of Applied Physiology 39(3):434–443. DOI: 10.1152/jappl.1975.39.3.434. Human experiments describing pruritus, skin gas-bubble lesions and vestibular effects when nitrogen/neon-containing breathing gas was combined with a helium environment at stable ambient pressure.

Karreman G, Lambertsen CJ. · 1977

Kinetics of isobaric counterdiffusion. Bulletin of Mathematical Biology 39(5):587–595. DOI: 10.1007/BF02461204. Mathematical treatment of inert-gas counterdiffusion kinetics.

Cowley JR, Allegra C, Lambertsen CJ. · 1979

Subcutaneous tissue gas space pressure during superficial isobaric counterdiffusion. Journal of Applied Physiology 47(1):224–227. DOI: 10.1152/jappl.1979.47.1.224. Experimental work examining gas-phase development in superficial tissue during counterdiffusion.

Graves DJ, Idicula J, Lambertsen CJ, Quinn JA. · 1973

Bubble formation in physical and biological systems: a manifestation of counterdiffusion in composite media. Science 179(4073):582–584. DOI: 10.1126/science.179.4073.582. Describes counterdiffusion-induced supersaturation and bubble formation in composite physical and biological systems.

Risberg J, Hope A. · 2001

Thermal insulation properties of argon used as a dry suit inflation gas. Undersea & Hyperbaric Medicine 28(3):137–143. Human cold-water comparison of argon and air that found no significant improvement in measured thermal comfort or body cooling under the tested conditions.

Vrijdag XCE, van Ooij PJAM, van Hulst RA. · 2013

Argon used as dry suit insulation gas for cold-water diving. Extreme Physiology & Medicine 2:17. DOI: 10.1186/2046-7648-2-17. Found no added thermal benefit of argon over air in the specific one-hour, 13°C test conditions. The drysuits were deliberately flushed by repeated deflation and inflation cycles, making this especially relevant when discussing the claim that argon only works if the suit is purged before the dive.

How to read this page: where evidence comes from controlled hyperbaric or saturation-type experiments, the text deliberately says so. Those findings establish the underlying mechanism but should not automatically be interpreted as a quantified risk for every recreational or technical drysuit dive.

This website uses cookies. By continuing to use this site, you accept our use of cookies.  Learn more