GAS PLANNING
& MINIMUM GAS
Gas planning is not about deciding how much gas you hope to use. It is about determining how much gas must remain available to manage a credible failure and get the team from the point of maximum need to the next reliable gas source.
MINIMUM GAS IS A RESERVE WITH A JOB.
Minimum gas is the amount of usable breathing gas that must still be available when the team begins the contingency. It is calculated from a defined scenario — for example, a loss of one diver's gas at the deepest point — and must cover the team until another reliable gas source is reached.
For a team emergency, calculate for the divers who must breathe from the available gas source, using an appropriate elevated emergency RMV.
BUILD THE PLAN FROM THE FAILURE.
1 · Who breathes?
How many divers may need to breathe from the available gas supply?
2 · At what pressure?
Gas consumption rises with ambient pressure. Deep minutes are expensive minutes.
3 · For how long?
Include problem recognition, gas sharing, ascent or exit, stops and transitions required by the scenario.
4 · Where is the next reliable gas source? Minimum gas ends only when the team reaches gas that can actually support the next part of the contingency.
TWO DIVERS AT 45 M.
This is a deliberately simplified teaching example — not a complete decompression gas plan. Assume two divers must breathe from one available back-gas supply after a failure at 45 m.
Normal RMV
per diver
Emergency factor
giving 30 L/min per diver
Team RMV
2 × 30 L/min
FROM 45 M TO 21 M.
One minute at 45 m
Ambient pressure ≈ 5.5 bar.
This minute allows for recognition, donation and establishing control before ascent.
Ascend 45 → 21 m at 9 m/min
Distance = 24 m. Time = 24 ÷ 9 ≈ 2.67 min. For this simplified segment calculation, average depth = 33 m → average pressure ≈ 4.3 bar.
Total gas to reach 21 m
So the team needs approximately 1,020 litres of usable back gas for this defined part of the contingency.
Important: 1,020 L is not automatically the final minimum-gas number for a real dive. A real plan must include the actual cylinders, starting pressures, ascent/decompression obligations, gas switches, team configuration, emergency RMV assumptions and the point at which another reliable gas supply becomes available.
THE CYLINDER TURNS GAS VOLUME INTO A PRESSURE LIMIT.
If the calculated reserve is 1,020 L and the usable gas is in a twinset with a nominal combined water volume of 24 L, a simple ideal-gas teaching conversion would be:
That pressure is the theoretical gas quantity represented by the calculated volume. Real planning should also account for practical pressure margins, gauge uncertainty and the limitations of simple ideal-gas conversions at high cylinder pressures.
THE NAME MATTERS LESS THAN THE METHOD.
Different training systems and diving communities use terms such as minimum gas, rock bottom or reserve gas. The operational details may differ, but the useful question remains the same: what credible failure are we planning for, and how much gas does the team need to reach the next safe gas source?
A reserve that has not been connected to a specific failure, depth, team demand and exit/ascent requirement is only a number — not a gas plan.
“Do not start gas planning with the cylinder pressure. Start with the failure you need the gas to solve.”
PLAN THE GAS BEFORE YOU NEED IT.
Plan as a team
The reserve must support the divers who may depend on the same gas source during the contingency.
Pressure matters
RMV is converted to actual gas demand by ambient pressure and time.
Define the endpoint
The calculation continues until a genuinely reliable alternative gas source is reached.
THE BASIS FOR GAS PLANNING & MINIMUM GAS.
These sources support the planning principles used on this page: respiratory minute volume, ambient-pressure gas consumption, team emergency gas, ascent planning and maintaining enough usable gas to reach the next reliable source.
Global Underwater Explorers
TDI
Divers Alert Network
NOAA
Mitchell, S.J. et al.
Minimum Gas / Rock Bottom
A value such as “50 bar reserve” is not automatically a valid minimum-gas plan. Required reserve changes with depth, cylinder volume, team configuration, respiratory demand, ascent profile, decompression obligation and the location of the next reliable breathing-gas source.