THE
RULE OF
FIFTHS
A practical screening rule for certain helium-to-nitrogen gas switches. It asks one simple question: is the increase in nitrogen small enough compared with the decrease in helium?
Operational screening relationship · not a decompression model
SCREEN THE GAS SWITCH — NOT JUST THE MOD.
Technical divers often evaluate a decompression gas by oxygen exposure and maximum operating depth. With trimix, there is another question: how much does the switch replace helium with nitrogen?
The Rule of Fifths provides a simple screen for that inert-gas change. It belongs in the context of the planned ascent and is not a substitute for a decompression algorithm, appropriate training or judgement.
NOAA states that the increase in nitrogen percentage in a decompression gas mixture should be no more than one fifth of the decrease in helium percentage from the previous gas.
WHAT DOES 1:5 MEAN?
Compare the increase in nitrogen fraction with the magnitude of the decrease in helium fraction across the switch.
The nitrogen increase should not exceed one fifth of the helium decrease. The operational rule is expressed using gas percentage or gas fraction.
At one gas-switch depth, both corresponding partial-pressure changes scale with the same ambient pressure, so the numerical 1:5 ratio is unchanged.
FOUR STEPS.
Find FN₂ and FHe
Identify the nitrogen and helium fractions in the gas breathed immediately before the switch.
Find the new fractions
Identify FN₂ and FHe in the gas the diver intends to breathe after the switch.
Find ΔFN₂ and ΔFHe
Calculate the nitrogen increase and the helium decrease across the switch.
Apply 1:5
Compare the nitrogen increase with one fifth of the magnitude of the helium decrease.
45% He → 0% He · 37% N₂ → 50% N₂
Helium = 45%
Nitrogen = 37%
Helium = 0%
Nitrogen = 50%
He decrease = 45 percentage points
N₂ increase = 13 percentage points
45 ÷ 5 = 9 percentage points
Actual N₂ rise = 13
13 > 9 → exceeds the Rule of Fifths screening limit. Helium falls by 45 percentage points; one fifth is 9. Nitrogen rises by 13 percentage points.
THE SIZE OF THE CHANGE MATTERS.
The rule compares the change in helium with the change in nitrogen. It is the size of those changes — not simply the name of the new gas — that is screened.
N₂ fraction lower
He fraction higher
N₂ fraction higher
He fraction lower
At the same depth, compare the change in helium and nitrogen gas fractions.
“Do not look at a gas switch only as a change in oxygen. With trimix, always look at what happens to both helium and nitrogen at the actual switch depth.”
THREE IMPORTANT LIMITS.
It is a screening rule
The 1:5 relationship helps evaluate a particular inert-gas change. It does not calculate a decompression schedule.
Use gas fractions consistently
Apply the rule to the change in helium and nitrogen percentage or fraction across the planned gas switch. Partial pressure remains important to the wider dive plan.
Context still matters
Exposure history, ascent strategy, decompression model, gas selection and diver condition remain part of the complete plan.
RULE AND PHYSIOLOGY — KEPT SEPARATE.
The operational rule and the physiological background are deliberately referenced separately.
NOAA Diving Standards & Safety Manual
OC Decompression & Mixed Gas Diving, section 7.7.3 C.4 in the current manual. NOAA describes the Rule of Fifths for helium-to-nitrogen gas switches.
NOAA resources →Doolette & Mitchell, 2003
Biophysical basis for inner ear decompression sickness. Journal of Applied Physiology 94(6):2145–2150. DOI: 10.1152/japplphysiol.01090.2002.
PubMed →Mitchell & Doolette, 2015
Pathophysiology of inner ear decompression sickness: potential role of the persistent foramen ovale. Diving and Hyperbaric Medicine 45(2):105–110.
PubMed →Important distinction: NOAA is cited for the operational Rule of Fifths. Doolette & Mitchell are cited for physiological and biophysical context; they are not presented as the originators of the Rule of Fifths.
NEXT IN THE KNOWLEDGE CENTRE.
Gas Density & Breathing
How breathing-gas density influences work of breathing and technical dive planning.
CORE TOPICIsobaric Counter Diffusion
Why helium and nitrogen moving in opposite directions can matter during gas switches.
CORE TOPICHow Decompression Works
Pressure gradients, inert-gas uptake, elimination and controlled ascent.
DIVER PHYSIOLOGYHydration & Diving
Why hydration matters before and after a dive.