DECOMPRESSION
MODELS
A decompression model does not know what is happening inside your body. It calculates a mathematical representation of inert-gas uptake and elimination, then applies rules that determine when ascent is permitted. Understanding that distinction is fundamental to technical diving.
TISSUE COMPARTMENTS ARE MATHEMATICAL.
Bühlmann-type dissolved-gas models represent the diver with multiple theoretical compartments, each assigned characteristic inert-gas half-times. A compartment is not a specific organ such as the brain, muscle or bone.
The compartments are mathematical tools that react at different rates to changes in inspired inert-gas pressure. At any point in the dive, one or more compartments may become important in determining the decompression ceiling.
HALF OF WHAT IS STILL MISSING.
A compartment half-time is the time required to complete 50% of the remaining pressure change toward a new equilibrium. It is not a linear filling rate. Every half-time halves the difference that still remains.
Example: if a compartment starts at 1 bar and the new equilibrium is 5 bar, the sequence is 1 → 3 → 4 → 4.5 → 4.75 bar. Each step removes half of the remaining difference.
1 half-time
50% of the total pressure change completed.
2 half-times
75% completed. Only 25% of the original difference remains.
3 half-times
87.5% completed. The curve approaches equilibrium progressively.
HALF OF WHAT IS STILL MISSING.
Before using real diving pressures, start with simple numbers. Imagine a 20-minute compartment that starts at 1.0 bar. After a change in depth or breathing gas, its new equilibrium pressure is 5.0 bar.
0 → 20 min
Difference = 5 − 1 = 4 bar.
Half = 2 bar.
1 + 2 = 3 bar.
20 → 40 min
Now only 5 − 3 = 2 bar remains.
Half = 1 bar.
3 + 1 = 4 bar.
40 → 60 min
Now only 5 − 4 = 1 bar remains.
Half = 0.5 bar.
4 + 0.5 = 4.5 bar.
The key: “20-minute compartment” does not mean that the compartment is full after 20 minutes. It means that every 20 minutes it completes half of the pressure change that still remains.
WHAT IS INSPIRED PN₂?
Inspired PN₂ is the partial pressure of nitrogen in the humidified inspired gas used as the driving pressure in the compartment calculation.
Gas entering the respiratory system becomes humidified. Water vapour therefore occupies part of the total pressure, so the available pressure for the breathing gases is slightly lower than ambient pressure.
At body temperature, this example uses a water-vapour pressure of approximately 0.0627 bar.
Why it matters: the inspired PN₂ is the pressure that the theoretical N₂ compartment moves toward. The compartment does not instantly become 3.110 bar — its half-time determines how quickly it approaches that value.
AIR AT 30 M · 20-MINUTE N₂ COMPARTMENT.
Now we use exactly the same principle with realistic nitrogen pressures. Assume constant depth at 30 m, air, water-vapour pressure of 0.0627 bar and a compartment initially equilibrated with air at the surface.
Starting PN₂
(1.0 − 0.0627) × 0.79
= 0.740 bar
Target PN₂ at 30 m
(4.0 − 0.0627) × 0.79
= 3.110 bar
Total change
3.110 − 0.740
= 2.370 bar
The numbers are different, but the mechanism is identical to the 1 → 5 bar example: after each 20-minute half-time, the compartment travels halfway across the pressure difference that still remains.
THE MODEL ASKS: HOW FAR MAY WE ASCEND?
During ascent, ambient pressure decreases faster than some compartments can eliminate inert gas. The resulting supersaturation is compared with the decompression model's permitted limit. In Bühlmann, that boundary is described by compartment-specific a and b coefficients — the M-value relationship.
DIFFERENT MODELS ASK DIFFERENT QUESTIONS.
Bühlmann / ZHL
Primarily a dissolved-gas compartment model. It tracks inert-gas pressures and constrains ascent with M-values, often modified by Gradient Factors.
VPM / RGBM concepts
Bubble-model approaches attempt to include bubble formation or bubble-growth behavior in decompression calculations. Implementations and assumptions vary.
No model sees the diver
Neither model type directly measures your actual bubbles, perfusion, hydration, workload, thermal stress or individual susceptibility during the dive.
THE COMPUTER CALCULATES — THE DIVER INTERPRETS.
A dive computer can calculate a decompression obligation to great numerical precision, but precision is not the same as physiological certainty. The output depends on the chosen model, coefficients, Gradient Factors or other conservatism settings, the recorded pressure profile and the breathing gases entered into the computer.
Technical-diving principle: understand what your computer is modeling, which settings you have selected, and how those settings influence the ascent profile. Do not treat a displayed ceiling as a direct measurement of your body's decompression state.
“A decompression model produces a schedule. It does not produce certainty. The skill is understanding what the model assumes — and then diving the plan with appropriate margins.”
UNDERSTAND THE MODEL.
Compartments are theoretical
They describe different inert-gas response rates, not individual anatomical tissues.
Half-times describe kinetics
Each half-time removes half of the remaining pressure difference toward equilibrium.
Ceilings are calculated
A decompression ceiling is a model output based on tissue calculations and permitted gradients — not a sensor reading from the diver.
BUILD THE MODEL STEP BY STEP.
M-Values
The model boundary that defines tolerated compartment pressure.
Gradient Factors
How GF Low and GF High modify the Bühlmann M-value gradient.
How Decompression Works
Pressure gradients and inert-gas movement through the body.
Gas Density & Breathing
Why respiratory mechanics also matter in technical diving.
THE SCIENCE BEHIND DECOMPRESSION MODELS.
These sources support the concepts used on this page: theoretical tissue compartments, half-times, inspired inert-gas pressure, Bühlmann ZHL-16 and Gradient Factors.
Bühlmann, A.A.
Schreiner, H.R. & Kelley, P.L.
Baker, E.C.
Baker, E.C.
Divers Alert Network
Shearwater Research
A decompression model calculates theoretical inert-gas behaviour. Compartments and half-times are mathematical constructs used to approximate gas kinetics; they are not direct measurements of individual anatomical tissues, bubbles or decompression sickness risk.