KNOWLEDGE · CCR PHYSIOLOGY

CCR PHYSIOLOGY
& PO₂ CONTROL

A closed-circuit rebreather changes the relationship between depth, oxygen fraction and oxygen partial pressure. The diver is no longer simply breathing a fixed gas mix. Understanding what the loop is doing — and what the body is actually exposed to — is fundamental to CCR diving.

CCR LOOPPO₂O₂ ADDEDO₂ CONSUMEDDEPTH / PRESSUREDILUENT + METABOLISM
START WITH THE PRINCIPLE

PO₂ — NOT O₂ PERCENTAGE — DRIVES EXPOSURE.

Oxygen physiology is driven primarily by oxygen partial pressure. On open circuit, a fixed oxygen fraction means PO₂ rises and falls directly with ambient pressure. On CCR, the system adds oxygen to the breathing loop in order to maintain a selected target PO₂.

PO₂ = Pambient × FO₂

The same relationship still applies. What changes is that the oxygen fraction in the loop can vary as the CCR maintains the target PO₂.

SIMPLE EXAMPLE · OC VS CCR

FIXED FO₂ OR TARGET PO₂?

OPEN CIRCUIT
Fixed FO₂ → PO₂ changes with depth

With a fixed breathing gas, the oxygen fraction does not change. As ambient pressure increases or decreases, oxygen partial pressure changes with it.

EAN32 example

10 m: 2.0 × 0.32 = 0.64 bar PO₂
30 m: 4.0 × 0.32 = 1.28 bar PO₂
40 m: 5.0 × 0.32 = 1.60 bar PO₂

CLOSED CIRCUIT REBREATHER
Target PO₂ → loop FO₂ changes with depth

With a CCR at a constant setpoint, the controller attempts to maintain the selected PO₂. The oxygen fraction that mathematically corresponds to that PO₂ therefore changes as ambient pressure changes.

Setpoint 1.3 example

10 m: 1.3 ÷ 2.0 = 65.0% O₂
30 m: 1.3 ÷ 4.0 = 32.5% O₂
60 m: 1.3 ÷ 7.0 = 18.6% O₂

OPEN CIRCUIT · EAN32 CCR · SETPOINT 1.3 10 mFO₂ 32%PO₂ 0.64 30 mFO₂ 32%PO₂ 1.28 40 mFO₂ 32%PO₂ 1.60 10 mPO₂ 1.30FO₂ 65.0% 30 mPO₂ 1.30FO₂ 32.5% 60 mPO₂ 1.30FO₂ 18.6%

Important: the CCR does not select “65%”, “32.5%” or “18.6%” as breathing mixes. These values simply show the oxygen fraction that corresponds mathematically to a PO₂ of 1.3 bar at each ambient pressure. The CCR measures PO₂ and adds oxygen as required; actual loop composition is also influenced by diluent, metabolism, depth changes and loop venting.

THE CONTROL LOOP

MEASURE → COMPARE → ADD OXYGEN.

In an electronic CCR, oxygen sensors provide PO₂ information to the controller. The measured value is compared with the selected setpoint. When PO₂ is below the control target, the system can energize the oxygen solenoid and add oxygen to the loop.

The diver must still monitor the displayed PO₂ and understand that sensors, electronics, solenoid operation and gas addition can fail. The setpoint is a control target — not proof of the actual breathing-loop PO₂.

O₂ SENSORSCONTROLLERO₂ SOLENOIDMEASURED PO₂ADD O₂ IF REQUIRED
WHAT THE DIVER CHANGES

DEPTH CHANGES PO₂ BEFORE THE CONTROLLER CAN CORRECT IT.

Descent

Increasing ambient pressure compresses the loop and raises gas partial pressures. Diluent addition, oxygen metabolism and control strategy all influence the resulting loop PO₂.

Constant depth

The diver consumes oxygen metabolically. The CCR replaces oxygen to maintain the target PO₂ while CO₂ is removed by the scrubber.

Ascent

Falling ambient pressure tends to reduce PO₂. Maintaining setpoint can require oxygen addition while expanding loop gas must also be managed and vented.

PHYSIOLOGY

THE LOOP CONNECTS OXYGEN, CO₂ AND WORK OF BREATHING.

CCR physiology cannot be reduced to PO₂ alone. Elevated inspired CO₂, inadequate ventilation and high work of breathing can increase physiological stress and interact with oxygen exposure. A correct displayed setpoint does not compensate for poor ventilation or CO₂ retention.

WORK OFBREATHINGVENTILATION& CO₂OXYGENEXPOSURE
SETPOINT ≠ MEASUREMENT

THE NUMBER YOU SELECT IS NOT THE NUMBER YOU BREATHE.

A selected setpoint such as 1.3 bar tells the controller what PO₂ it should attempt to maintain. The actual loop PO₂ must be measured. Sensor disagreement, calibration errors, oxygen-addition faults, rapid depth changes and other failures can create a difference between target and reality.

This is why CCR training emphasizes monitoring, sensor validation, response to high and low PO₂, manual control capability and appropriate bailout planning.

INSTRUCTOR INSIGHT

“A setpoint is an instruction to the rebreather. PO₂ is what the diver is actually exposed to. Never confuse the two.”

KIM HENRIKSEN · TECDIVINGDK
THREE PRINCIPLES

UNDERSTAND THE LOOP.

PO₂ drives oxygen exposure

Oxygen percentage alone does not describe the physiological exposure without ambient pressure.

CCR FO₂ changes

At constant setpoint, loop oxygen fraction changes with depth because ambient pressure changes.

Measure — do not assume

The selected setpoint is a target. Safe CCR operation depends on monitoring the actual measured loop PO₂.

REFERENCES & FURTHER READING

THE SCIENCE BEHIND CCR PHYSIOLOGY & PO₂ CONTROL.

These sources support the physiological and operational concepts used on this page: oxygen partial pressure, CCR setpoint control, loop-gas dynamics, oxygen exposure and the limitations of electronic PO₂ monitoring.

CCR PHYSIOLOGY

Vann, R.D. et al.

Decompression Illness. Lancet, 2011; 377:153–164.
Provides physiological background for inert-gas loading, ambient pressure and decompression relevant to both open-circuit and closed-circuit diving.
OXYGEN PHYSIOLOGY

Divers Alert Network

Oxygen Toxicity. DAN medical and diving safety guidance.
Supports the distinction between CNS and pulmonary oxygen toxicity and the importance of managing oxygen partial pressure and exposure.
CCR OPERATION

JJ-CCR

JJ-CCR Rebreather User Manual.
Operational reference for electronically controlled oxygen addition, PO₂ monitoring, setpoints, sensors and loop management on a modern eCCR.
CCR SAFETY

Mitchell, S.J. & Doolette, D.J.

Rebreather physiology and diving medicine literature.
Supports the central CCR principle that the diver must manage inspired-gas physiology rather than treating displayed setpoint as proof of actual breathing-loop conditions.
OXYGEN EXPOSURE

NOAA

NOAA Diving Manual / NOAA Diving Standards & Safety Manual.
Operational reference for oxygen partial-pressure limits, exposure management and oxygen-diving procedures.
TECHNICAL IMPLEMENTATION

Shearwater Research

Petrel 3 Technical Manual.
Documents PO₂ display, external oxygen-sensor monitoring, setpoint-related functions and decompression calculations used with CCR diving.
SETPOINT ≠ MEASURED PO₂

A CCR setpoint is the control system’s target. The diver breathes the actual loop gas, not the setpoint number. Sensor accuracy, oxygen addition, metabolism, diluent addition, depth changes and loop venting can all affect the measured PO₂ and gas composition.